Tiger's Eye Controllers
Microprocessor Based, Solid State Programmable Logic Controller for Packaged Pump Systems

  • State-of-the-Art System Control:
  • Mark II Pressure Booster - Constant Speed
  • Mark III Tank Level
  • Mark IV HVAC Multi-Zone - Constant Speed
  • Mark V Pressure Booster - Variable Speed
  • Mark VI HVAC Multi-Zone - Variable Speed
  • Mark VII Chiller Sequencing - Variable Speed
  • Mark VIII Data Center

Nerve center to all TIGERFLOW systems, TIGER'S EYE Microprocessor Based, Solid State Programmable Logic Controllers (PLC) provide unparalleled control for packaged systems. Transducer supplied signals provide more accurate and precise control with less hardware.

TIGERFLOW Control Sequences:

  • Pressure Sequencing
  • Flow Sequencing
  • Suction, Discharge Pressure
  • Level Sequencing
  • Best Efficiency Monitoring
  • Wire to Water Efficiency
  • Variable Primary Control
  • Primary/Secondary Control
  • Chiller Sequencing
  • Boiler Sequencing
  • BTU Calculations & Sequences
  • Variable Volume, Constant Speed
  • Cooling Tower Control
  • Automated Valve Control
  • Temperature Control
  • Data Logging
  • Energy Management System Interface

 

 

E-SERIES Variable Speed Booster System Specification

 

UL/C-UL LISTED, NEMA 4 (Duplex) (Triplex)(Quadraplex) TIGER'S EYE MARK V  VARIABLE SPEED  SOLID STATE,, POWER & CONTROL PANEL:

(*)            U.L. 508 LABEL

(*)            -MICRO CONTROLLER WITH PLC AND HMI TECHNOLOGY

(*)            -TOUCH SCREEN OPERATOR INTERFACE

                -HOA PUMP OPERATION

                -PRESSURE SEQUENCING

                -FLOW SEQUENCING (requires optional flowmeter)

                -FLOW TOTALIZATION )requires optional flowmeter)

                -OPERATOR AJUSTABLE SETTINGS

                                Pump Start/Stop pressures

                                Pump ON and OFF delay times

                                Alarm settings

                                                Low Suction pressure

                                                Low System pressure

                                                High Suction Pressure

                                                Individual alarm ON / OFF delays

                                                Manual / Automatic alarm reset

                                                Pump failure On delay

                                High System economy mode

                                Pump alternation

                                                Automatic on lead pump shutdown

                                                Daily / weekly / monthly

                                                Manual alternation

                                -SEPARATE ALARM SILENCE AND RESET BUTTON

                                -EVENT HISTORY RECORDS LAST 10 EVENTS

                                                Pump starts / stops

                                                Alarm conditions

                                                Alarm acknowledgements

                                                Alarm reset

                                                Date and Time of each event                           

-SUCTION AND DISCHARGE PRESSURE READ OUT IN PSI

-INDIVIDUAL PUMP RUN INDICATOR

-8 PASSWORD PROTECTED LEVELS OF SECURITY

                Passwords field changeable

-TOUCH SAFE DC POWER SUPPLY

-24 v DC DIGITAL I/O

-MAXIMUM 256 I/O POINTS

-RS-485, TWO WIRE, HALF DUPLEX

-NETWORK COMMUNICATION

Nema I, variable frequency drives with PWM and operator interfaces, _______hp, 230/1/60 drives to convert to 230/3/460V

 ( )           THRU DOOR DISCONNECT(S) WITH INDIVIDUAL MOTOR CIRCUIT BREAKERS

( )            FVNR MAGNETIC STARTERS WITH 3-LEG OVERLOAD PROTECTION

 (1)          ALARM HORN AND RESET BUTTON

 (2)          PANEL MOUNTED S.S.PRESSURE TRANSDUCERS [(1) SUCTION, (1) DISCHARGE]

 

 

E-SERIES Constant Speed Booster Specification

 

UL/C-UL LISTED, NEMA 4 (Duplex) (Triplex)(Quadraplex) TIGER'S EYE MARK II SOLID STATE,, POWER & CONTROL PANEL:

(*)            U.L. 508 LABEL

(*)            -MICRO CONTROLLER WITH  PLC AND HMI TECHNOLOGY

-FLASH MAIN MEMORY

-EEPROM MEMORY FOR ALL USER SETPOINTS

(*)            -TOUCH SCREEN OPERATOR INTERFACE

                -HOA PUMP OPERATION

                -PRESSURE SEQUENCING

                -FLOW SEQUENCING (requires optional flowmeter)

                -FLOW TOTALIZATION )requires optional flowmeter)

                -OPERATOR AJUSTABLE SETTINGS

                                Pump Start/Stop pressures

                                Pump ON and OFF delay times

                                Alarm settings

                                                Low Suction pressure

                                                Low System pressure

                                                High Suction Pressure

                                                Individual alarm ON / OFF delays

                                                Manual / Automatic alarm reset

                                                Pump failure On delay

                                High System economy mode

                                Pump alternation

                                                Automatic on lead pump shutdown

                                                Daily / weekly / monthly

                                                Manual alternation

                                -SEPARATE ALARM SILENCE AND RESET BUTTON

                                -EVENT HISTORY RECORDS LAST 10 EVENTS

                                                Pump starts / stops

                                                Alarm conditions

                                                Alarm acknowledgements

                                                Alarm reset

                                                Date and Time of each event                           

-SUCTION AND DISCHARGE PRESSURE READ OUT IN PSI

-INDIVIDUAL PUMP RUN INDICATOR

-8 PASSWORD PROTECTED LEVELS OF SECURITY

                Passwords field changeable

-TOUCH SAFE DC POWER SUPPLY

-24 v DC DIGITAL I/O

-MAXIMUM 256 I/O POINTS

-RS-485, TWO WIRE, HALF DUPLEX

-NETWORK COMMUNICATION

 (2)          THRU DOOR DISCONNECT(S) WITH INDIVIDUAL MOTOR CIRCUIT BREAKERS

(2)           FVNR MAGNETIC STARTERS WITH 3-LEG OVERLOAD PROTECTION

 (1)          ALARM HORN AND RESET BUTTON

 (2)          PANEL MOUNTED S.S.PRESSURE TRANSDUCERS [(1) SUCTION, (1) DISCHARGE]