DOWNLOAD PDF: Tiger's Eye Controllers
Tiger's
Eye Controllers
Microprocessor Based, Solid State Programmable Logic Controller for Packaged Pump Systems
- State-of-the-Art System Control:
- Mark II Pressure Booster - Constant Speed
- Mark III Tank Level
- Mark IV HVAC Multi-Zone - Constant Speed
- Mark V Pressure Booster - Variable Speed
- Mark VI HVAC Multi-Zone - Variable Speed
- Mark VII Chiller Sequencing - Variable Speed
- Mark VIII Data Center
Nerve center to all TIGERFLOW systems, TIGER'S EYE Microprocessor Based, Solid State Programmable Logic Controllers (PLC) provide unparalleled control for packaged systems. Transducer supplied signals provide more accurate and precise control with less hardware.
|
TIGERFLOW
Control
Sequences:
- Pressure
Sequencing
- Flow
Sequencing
- Suction,
Discharge
Pressure
- Level
Sequencing
- Best
Efficiency
Monitoring
- Wire
to
Water
Efficiency
- Variable
Primary
Control
- Primary/Secondary
Control
- Chiller
Sequencing
- Boiler
Sequencing
- BTU
Calculations & Sequences
- Variable
Volume,
Constant
Speed
- Cooling
Tower
Control
- Automated
Valve
Control
- Temperature
Control
- Data
Logging
- Energy
Management
System
Interface
|
 |


E-SERIES
Variable
Speed Booster
System
Specification
UL/C-UL
LISTED, NEMA
4 (Duplex)
(Triplex)(Quadraplex)
TIGER'S EYE
MARK V VARIABLE
SPEED SOLID
STATE,, POWER & CONTROL
PANEL:
(*) U.L.
508 LABEL
(*) -MICRO
CONTROLLER
WITH PLC
AND HMI TECHNOLOGY
(*) -TOUCH
SCREEN OPERATOR
INTERFACE
-HOA
PUMP OPERATION
-PRESSURE
SEQUENCING
-FLOW
SEQUENCING
(requires
optional
flowmeter)
-FLOW
TOTALIZATION
)requires
optional
flowmeter)
-OPERATOR
AJUSTABLE
SETTINGS
Pump
Start/Stop
pressures
Pump
ON and OFF
delay times
Alarm
settings
Low
Suction pressure
Low
System pressure
High
Suction Pressure
Individual
alarm ON
/ OFF delays
Manual
/ Automatic
alarm reset
Pump
failure On
delay
High
System economy
mode
Pump
alternation
Automatic
on lead pump
shutdown
Daily
/ weekly
/ monthly
Manual
alternation
-SEPARATE
ALARM SILENCE
AND RESET
BUTTON
-EVENT
HISTORY RECORDS
LAST 10 EVENTS
Pump
starts /
stops
Alarm
conditions
Alarm
acknowledgements
Alarm
reset
Date
and Time
of each event
-SUCTION
AND DISCHARGE
PRESSURE
READ OUT
IN PSI
-INDIVIDUAL
PUMP RUN
INDICATOR
-8
PASSWORD
PROTECTED
LEVELS OF
SECURITY
Passwords
field changeable
-TOUCH
SAFE DC POWER
SUPPLY
-24
v DC DIGITAL
I/O
-MAXIMUM
256 I/O POINTS
-RS-485,
TWO WIRE,
HALF DUPLEX
-NETWORK
COMMUNICATION
Nema
I,
variable
frequency
drives
with
PWM and
operator
interfaces,
_______hp,
230/1/60
drives
to convert
to 230/3/460V
(
) THRU
DOOR DISCONNECT(S)
WITH INDIVIDUAL
MOTOR CIRCUIT
BREAKERS
(
) FVNR
MAGNETIC
STARTERS
WITH 3-LEG
OVERLOAD
PROTECTION
(1) ALARM
HORN AND
RESET BUTTON
(2) PANEL
MOUNTED S.S.PRESSURE
TRANSDUCERS
[(1) SUCTION,
(1) DISCHARGE]
E-SERIES
Constant
Speed Booster
Specification
UL/C-UL
LISTED, NEMA
4 (Duplex)
(Triplex)(Quadraplex)
TIGER'S EYE
MARK II SOLID
STATE,, POWER & CONTROL
PANEL:
(*) U.L.
508 LABEL
(*) -MICRO
CONTROLLER
WITH PLC
AND HMI TECHNOLOGY
-FLASH
MAIN MEMORY
-EEPROM
MEMORY FOR
ALL USER SETPOINTS
(*) -TOUCH
SCREEN OPERATOR
INTERFACE
-HOA
PUMP OPERATION
-PRESSURE
SEQUENCING
-FLOW
SEQUENCING
(requires
optional flowmeter)
-FLOW
TOTALIZATION
)requires
optional flowmeter)
-OPERATOR
AJUSTABLE
SETTINGS
Pump
Start/Stop
pressures
Pump
ON and OFF
delay times
Alarm
settings
Low
Suction pressure
Low
System pressure
High
Suction Pressure
Individual
alarm ON /
OFF delays
Manual
/ Automatic
alarm reset
Pump
failure On
delay
High
System economy
mode
Pump
alternation
Automatic
on lead pump
shutdown
Daily
/ weekly /
monthly
Manual
alternation
-SEPARATE
ALARM SILENCE
AND RESET
BUTTON
-EVENT
HISTORY RECORDS
LAST 10 EVENTS
Pump
starts / stops
Alarm
conditions
Alarm
acknowledgements
Alarm
reset
Date
and Time of
each event
-SUCTION
AND DISCHARGE
PRESSURE READ
OUT IN PSI
-INDIVIDUAL
PUMP RUN INDICATOR
-8
PASSWORD PROTECTED
LEVELS OF
SECURITY
Passwords
field changeable
-TOUCH
SAFE DC POWER
SUPPLY
-24
v DC DIGITAL
I/O
-MAXIMUM
256 I/O POINTS
-RS-485,
TWO WIRE,
HALF DUPLEX
-NETWORK
COMMUNICATION
(2) THRU
DOOR DISCONNECT(S)
WITH INDIVIDUAL
MOTOR CIRCUIT
BREAKERS
(2) FVNR
MAGNETIC STARTERS
WITH 3-LEG
OVERLOAD PROTECTION
(1) ALARM
HORN AND RESET
BUTTON
(2) PANEL
MOUNTED S.S.PRESSURE
TRANSDUCERS
[(1) SUCTION,
(1) DISCHARGE]
|